BDNTF - COM-4D LEAD/ACID STORAGE BATTERY
- MSDS: BDNTF
- Manufacturer: EXIDE CORP
- Product Name: COM-4D LEAD/ACID STORAGE BATTERY
- National Stock Number: 6140-00-250-1981
Product Identification
Product ID:COM-4D LEAD/ACID STORAGE BATTERY
MSDS Date:03/24/1986
FSC:6140
NIIN:00-250-1981
MSDS Number: BDNTF
Responsible Party
READING, PA 19612-4205
US
Emergency Phone: 215-378-0798
Info Phone: 215 378-0798
Cage: 20038
Contractor
Telephone: 610-378-0500/0798
Cage: 20038
Ingredients
LEAD (SARA III)
CAS: 7439-92-1
RTECS: OF7525000
Fraction By Weight: >60%
OSHA PEL 0.05 MG/M3;1910.1025
ACGIH TLV: 0.15 MG/M3;DUST 9192
EPA Report Quantity: 1 LB
DOT Report Quantity: 1 LB
ANTIMONY (SARA III)
CAS: 7440-36-0
RTECS: CC4025000
Fraction By Weight: >2%
OSHA PEL 0.5 MG/M3
ACGIH TLV: 0.5 MG SB/M3; 9192
EPA Report Quantity: 5000 LBS
DOT Report Quantity: 5000 LBS
ARSENIC (SARA III)
CAS: 7440-38-2
RTECS: CG0525000
Fraction By Weight: <0.2%
OSHA PEL 0.5 MG/M3 (AS)
ACGIH TLV: 0.01,A1 MG/M3; 9394
EPA Report Quantity: 1 LB
DOT Report Quantity: 1 LB
CALCIUM, METAL
CAS: 7440-70-2
RTECS: EV8040000
Fraction By Weight: <0.2%
CALCIUM, METAL
CAS: 7440-70-2
RTECS: EV8040000
Fraction By Weight: 0.2%
TIN
CAS: 7440-31-5
RTECS: XP7320000
Fraction By Weight: 0.2%
OSHA PEL 2 MG/M3
ACGIH TLV: 2 MG/M3; 9192
POLYPROPYLENE
CAS: 9003-07-4
RTECS: UD1842000
Fraction By Weight: <10%
POLYSTYRENE
CAS: 9003-53-6
RTECS: WL6475000
Fraction By Weight: <10%
STYRENE ACRYLONITRILE
CAS: 9003-54-7
Fraction By Weight: <10%
ACRYLONITRILE BUTADIENE STYRENE
CAS: 9003-56-9
Fraction By Weight: <10%
STYRENE BUTADIENE
CAS: 9003-55-8
Fraction By Weight: <10%
POLYVINYLCHLORIDE
CAS: 9002-86-2
Fraction By Weight: <10%
POLYCARBONATE
Fraction By Weight: <10%
HARD RUBBER
Fraction By Weight: <10%
Hazards
LD50 LC50 Mixture:ORAL RAT LD50 IS NOT KNOWN
Routes of Entry: Inhalation:NO Skin:NO Ingestion:NO
Reports of Carcinogenicity:NTP:YES IARC:YES OSHA:NO
Health Hazards Acute and Chronic:PRODUCT CONTAINS LEAD AND SULFURIC
ACID. SULFURIC ACID IS A CORROSIVE CAUSING BURNS TO BODY TISSUES.
LEAD IS TOXIC AND SOME LEAD COMPOUNDS ARE LISTED AS CARCINOGENIC.
CONTACT WITH EITHER IS HIGHLY UNLIKELY TO OCCUR UNLESS THE CASE IS
BROKEN OR SPILLED, THEN ONLY CONTACT WITH THE ACID IS LIKELY.
Explanation of Carcinogenicity:LEAD COMPOUNDS ARE LISTED AS
CARCINOGENIC IN ANIMALS AND POSSILBY IN HUMANS.
Effects of Overexposure:CONTACT WITH SULFURIC ACID IS THE MOST LIKELY
EXPOSURE, PRODUCING IRRITATION OR BURNS TO THE BODY TISSUE
CONTACTED.
Medical Cond Aggravated by Exposure:NONE
First Aid
First Aid:FIRST AID IS GIVEN FOR SULFURIC ACID CONTACT. EYE:FLUSH
W/WATER 15 MIN, HOLD LIDS OPEN. SKIN:WASH WITH SOAP & WATER.
REMOVE CONTAMINATED CLOTHING AND LAUNDER BEFORE REUSE.
INHALED:REMOVE TO FRESH A IR. INGESTED:DO NOT INDUCE VOMITING.
GIVE 2 LARGE GLASSES OF MILK OR WATER AND GET IMMEDIATE MEDICAL
CARE. GIVE NOTHING BY MOUTH IF UNCONSCIOUS. IF IRRITATION
PERSISTS OR IS SEVERE,SEE A DOCTOR.
Fire Fighting
Flash Point:NON-FLAMMABLE
Autoignition Temp:Autoignition Temp Text:NONE
Extinguishing Media:PRODUCT IS NON FLAMMABLE. EXTINGUISH FIRE WITH
MEDIA APPROPRIATE FOR SOURCE OF FIRE.
Fire Fighting Procedures:FIRE FIGHTERS SHOULD USE NIOSH APPROVED SCBA &
FULL PROTECTIVE EQUIPMENT WHEN FIGHTING CHEMICAL FIRE. USE WATER
SPRAY TO COOL NEARBY CONTAINERS EXPOSED TO FIRE.
Unusual Fire/Explosion Hazard:WHEN BEING CHARGED THIS BATTERY GENERATES
HYDROGEN GAS WHICH MAY FORM EXPLOSIVE MIXTURES WITH AIR.
Accidental Release
Spill Release Procedures:IF ACID IS SPILLED, NEUTRALIZE. PLACE
REMAINDER IN AN ACID RESISTANT CONTAINER FOR RECYCLE OF THE LEAD.
Neutralizing Agent:SODIUM BICARBONATE OR LIME
Handling
Handling and Storage Precautions:STORE IN COOL, DRY AREA. PROTECT FROM
PHYSICAL DAMAGE. PROTECT TERMINALS FROM SHORT CIRCUITS.
Other Precautions:READ MANUFACTURERS LITERATURE AND FOLLOW
INSTRUCTIONS.
Exposure Controls
Respiratory Protection:RESPIRATOR WILL NOT NORMALLY BE NECESSARY. USE
NIOSH/MSHA APPROVED RESPIRATOR FOR ACID DUST/MIST IF EXPOSURE IS
ABOVE THE TLV/PEL. SEE 29 CFR 1910.134 FOR REGULATIONS PERTAINING
TO RESPIRATOR USE.
Ventilation:NOT NORMALLY REQUIRED. USE LOCAL EXHAUST DURING CHARGING
CYCLES TO AVOID AN EXPLOSIVE BUILD UP OF HYDROGEN GAS.
Protective Gloves:NONE (USE RUBBER IF ACID IS LEAKING)
Eye Protection:SAFETY GLASSES/SPLASH GOGGLES (LIQUID)
Other Protective Equipment:NORMAL WORK CLOTHING. PROTECT WITH
IMPERVIOUS APRON AND/OR BOOTS IF ACID IS LEAKING.
Work Hygienic Practices:USE GOOD INDUSTRIAL HYGIENE PRACTICE. AVOID
ALL CONTACT WITH ACID OR INTERNALS OF THE BATTERY. WASH AFTER
HANDLING.
Supplemental Safety and Health
BATTERY IS CLASSED AS AN ARTICLE PER OSHA HAZ COM STD AND INFORMATION
SUPPLIED FOR INFORMATION PURPOSES ONLY.
Chemical Properties
HCC:Z4
Appearance and Odor:AUTOMOTIVE STYLE BATTERY
Stability
Stability Indicator/Materials to Avoid:YES
ALKALIS
Stability Condition to Avoid:PROLONGED OVERCHARGE
Hazardous Decomposition Products:PRODUCES EXPOLOSIVE HYDROGEN GAS
DURING CHARGE CYCLE; EXPECIALLY WHEN OVERCHARGED.
Disposal
Waste Disposal Methods:DISPOSE I/A/W ALL FEDERAL, STATE AND LOCAL
REGULATIONS. MANUFACTURER SUGGESTS THAT DISPOSAL MAY BE DONE BY
FLUSHING NEUTRALIZED ACID TO DRAIN AND SENDING REMAINDER TO LEAD
RECLAIMER. DO NOT INCINERA TE!!!
Disclaimer (provided with this information by the compiling agencies):
This information is formulated for use by elements of the Department
of Defense. The United States of America in no manner whatsoever,
expressly or implied, warrants this information to be accurate and
disclaims all liability for its use. Any person utilizing this
document should seek competent professional advice to verify and
assume responsibility for the suitability of this information to their